Home >
A to Z Index
> Vital Signs Monitors >

  DINAMAP ProCare 400: BP, Heart Rate, Temp, Masimo SpO2 & Printer
 
 
Our Price: $2,610.00


Product Code: 1425


Description
 

The DINAMAP Procare 400 vitals signs monitor offers reliable automated BP, predictive temp, SpO2 and pulse rate using DINAMAP technology that's been clinically-proven as more accurate than competitive models. BP and pulse assessment is fast and easy: with the properly-sized BP cuff in place, press the large gray knob to take a reading. Industry-standard Masimo SET SpO2 is as easy as placing a finger clip. IVAC TurboTemp gives an accurate reading in just 7 seconds or less.

Features

  • The Procare 400 monitor sets the gold standard for vitals: DINAMAP NIBP, Masimo SET SpO2 and IVAC TurboTemp
  • IVAC Turbo-Temp complete in just 7 seconds
  • DINAMAP ProCare 120 - 420 monitors are covered by a 3-year parts and labor warranty
  • DINAMAP monitors feature a common user interface with GE monitors throughout the continuum of care, so floating nurses can assess patients with minimal training

Specifications

  • Blood Pressure Technique: Oscillometric measurement of systolic, diastolic and mean arterial pressure and pulse rate.
  • Cuff Inflation Adjustment Range:
    • Adult/Pediatric: 100 to 250 mmHg; 5 mmHg increments
    • Neonate: 100 to 140 mmHg; 5 mmHg increments
  • Cuff Pressure Range:
    • Adult/Pediatric: 0 to 290 mmHg*
    • Neonate: 0 to 140 mmHg*
    • *Automatically released if error condition is detected, power fails, or unit is switched off.
  • Target Inflation Pressure Range:
    • User-selectable cuff inflation pressure
    • Adult/Pediatric: nominally 160 mmHG
    • Neonate: nominally 110 mmHg
  • Determination Time:
    • 20 seconds to 45 seconds typical
    • Adult - 120 secs maximum
    • Neonate - 85 secs maximum
  • Accuracy:
    • Meets or exceeds SP 10-1992 AAMI standards
    • Pressure Preset Levels: Resolutions of 5 mmHg up to Maximum Adult/Neonate limits
    • Systolic Determinations:
      • Adult: Max: 245 mmHg; Min: 30 mmHg
      • Neonate: Max: 140 mmHg; Min: 40 mmHg
    • Diastolic Determinations:
      • Adult: Max: 195 mmHg; Min: 10 mmHg
      • Neonate: Max: 100 mmHg; Min: 20 mmHg
    • Determinations:
      • Adult: Max: 215 mmHg; Min: 15 mmHg
      • Neonate: Max: 115 mmHg; Min: 30 mmHg
  • IVAC® Temperature
    • Scale: °Fahrenheit(F) °Celsius(C)
    • RangePredictive mode:
      • Max: 42.2° C; 108.0°
      • Min: 31.6° C; 88.9° F
    • Monitor Mode:
      • Max: 42.2° C; 108.0° F
      • Min: 26.7° C; 80.0° F
    • Monitor Mode Accuracy: ±0.1°C ±0.2°F (when tested in a calibrated liquid bath; meets ASTM E1112, Table 1, in range specified)
    • Predictive Mode Accuracy: ±1.0°F ±0.6°C Determination time less than 60 seconds
  • Operating Modes:
    • AUTOMATIC, STAT, MANUAL Modes. Press START/STOP key to cancel.
  • Automatic Mode (Blood Pressure) Cycle Time:
    • Preset at 3 minutes.
    • User can select blood pressure determination frequency in varied increments between 1 and 120 minutes or operate by manual intervention.
    • The result of the most recent determination will be displayed for up to 90 minutes (AUTO) or 2 minutes (MANUAL).
  • Stat Mode: Rapid BP determination with early systolic display within 5-minute period.
  • Pulse Rate Range:
    • Adult/Pediatric: 30 - 200 BPM
    • Neonate: 30 200 BPM
  • Pulse Rate Accuracy: BP±3.5%
    • Overpressure Cut-off:
      • Adult/Pediatric: 300 - 330 mmHg
      • Neonate: 150 - 165 mmHg
  • Alarms
    • System Alarm Functions: Brief alarm test at power turn-on, alarm for no determination and a continuous alarm for microprocessor failure. Audible alarms with diagnostic codes displayed in pulse rate window for system failure.
    • Patient Alarm Functions:
      • Systolic: Preset at 30 mmHg low and 180 mmHg high
      • Diastolic: Preset at 15 mmHg low and 130 mmHg high
      • MAP: Preset at 50 mmHg low and 140 mmHg high for adult/pediatric and neonate
      • Pulse Rate: Preset at 40 BPM low and 160 BPM high
      • SpO2 Alarm Limits: Preset at off (100%) high and 90% low.
      • Range: High 51-100% (100% = off), Low 50-99%
      • Alarm Indicators: LED with audio alarm silence key. LED only flashes if audio alarm silenced and an alarm condition exists. Diagnostic data indicated on LCD.
  • Trend
    • Prior Data: Monitor stores 24 hours of data; up to 100 readings within time period.
  • Environmental
    • Operating Temperatures: +41°F to +104°F (+5°C to +40°C)
    • Atmospheric Pressure: 700 to 1060 hPa
    • Storage Temperature: -4°F to +122°F (-20°C to +50°C)
    • Humidity: 0 to 95% noncondensing
  • Power Requirements
    • Input Power:
      • AC input voltage: 100-240 VAC, 50/60 Hz (nominal) 90-253 VAC, 47-63 Hz (range), 50VA.
      • DC input voltage: 24 VDC, 36VA, supplied from a source conforming to IEC 601-1.
  • Fuse:
    • AC input is protected by two internal fuses.
    • DC input line is protected by an internal auto-resetting fuse.
    • Battery: 12 volt, 2.3 amp-hours protected by internal auto-resetting fuse.
  • Battery:
    • Sealed lead acid 12 volt 2.3 amp-hour, minimum operation time of 2 hours (5-minute auto cycle with adult cuff, temperature, SpO2 continuous and printer activated.
    • Longer battery life with vital signs at less frequent intervals). Time for full recharge is 2 hours from full discharge with monitor switched off.
    • Low Battery Warning: Flashing LED and audio tone alert user of low battery condition.
  • Power Cable:
    • Domestic: 10-ft, detachable, gray-jacketed, 16-gauge terminated with 3-prong hospital grade plug.
    • International: 7.5-ft (2.3m), detachable, black jacketed, 16-gauge terminated with appropriate plug.
  • Physical Dimensions
    • Dimensions: 9.8 in (H) x 9.8 in (W) x 6.9 in (D) [24.8 cm (H) x 24.8 cm (W) x 17.5 cm (D)]
    • Weight: 7.8 pounds; 3.5 kg (including battery)
    • Mountings: Self-supporting on rubber feet. Pole mountable. Carrying handle recessed into top of monitor.
    • Portability: Can be hand-carried by the recessed handle. When attached to the 3215 Rolling Stand, the monitor and accessories can be wheeled from patient to patient.
  • Printer
    • Paper Width: 1.75 inches
    • Writing Method: Direct thermal
    • Paper:
    • Environmental requirements: Temperature: 100°F (38°C) maximum, Humidity: 80% maximum
 



 Share your knowledge of this product with other customers... Be the first to write a review.



Browse for more products in the same category as this item:

A to Z Index
> Vital Signs Monitors